    Main characteristics:

    • -6 ranges: 50 ARMS, 100 ARMS, 150 ARMS, 200 ARMS, 240 ARMS, 250 ARMS
    • -Overcurrent detection set @ 2.93 x IPN on a dedicated pin
    • -Short response time: 3.5 µs
    • -Access to voltage reference
    • -Low offset and gain drift
    • -Measuring range up to 2.5 x IPN
    • -Small design (22 (W) x 45 (L) x 33 (H))
    • -High accuracy at 25°C: 1% of IPN at 105°C: 4.6% of IPN
    • -Creepage & clearance distances: 8 mm + CTI 600
    • -5 years warranty
     

    Features:

    • -DC, AC and pulse currents measurements with galvanic isolation
    • -Single supply 0, +5 V or 0, +3.3 V
    • -Isolation test voltage: up to 4.3 KVRMS / 50 Hz / 1 min
    • -Panel mounting models
    • -Big aperture 15 x 8 mm
    • -Operating temperature range: -40°C to +105°C
    • -Voltage output (0.8 V @ IPN)
    • -Bandwidth DC... 250 KHz (-3 dB)

     

    Standard compliance:

    • EN 50178 for industrial applications such as:
    • -Home appliances
    • -Solar inverters (MPPT)
    • -Combiner box for solar applications
    • -Small smart meters
    • -Servo drives
    • -AC Variable speed drives
    • -Power supplies
    • -UPS
    • -SMPS
    • -Forklift trucks
    • -Air-conditioners
    • -Current monitoring
    • -Welding applications
    • -UL 508 (UR marking)
    • -Using UL94-VO recognized materials
    • -European Directive EMC 2004 / 108 / EEC: CE marking
    • -Low voltage directive 2006 / 95 / EEC
    • -IEC 61010-1 safety

     

    Remarks:

    • -Bipolar currents measurements when single supplied 0/+5 V or 0/+3.3 V
    • -Fault reporting: Memory check

     

    Product search results
    Model Expand Primary
    Nominal
    Value
    Measuring
    Range
    Secondary
    Nominal
    Signal
    Supply
    Voltage (V)
    Accuracy (%) Mounting
     
    HO 100-S-0100 expand 100 A 250 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 100-S/SP33-1106 expand 100 A 250 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 150-S-0100 expand 150 A 375 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 150-S/SP33-1106 expand 150 A 375 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 200-S-0100 expand 200 A 500 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 200-S/SP33-1106 expand 200 A 500 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 240-S-0100 expand 240 A 600 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 250-S-0100 expand 250 A 625 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 250-S/SP33-1106 expand 250 A 625 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 50-S-0100 expand 50 A 125 A 0.8 V 5-5 Uni 1.25 On primary fastening, Panel
    HO 50-S/SP33-1106 expand 50 A 125 A 0.46 V 3.3-3.3 Uni 1.25 On primary fastening, Panel
     

     

    Similar Products

    LV 200-AW/2

    LV 200-AW/2

    CV 4-Voltage

    CV 4-Voltage

    LA 306-S

    LA 306-S

    LV 100

    LV 100

    HAT

    HAT

    LV 100-Voltage2

    LV 100-Voltage2

    IST

    IST

    HTA

    HTA

    LA 205 / 305 -S/ -T

    LA 205 / 305 -S/ -T

    LAX 100-NP

    LAX 100-NP

    HAS

    HAS

    HAL

    HAL

    HAZ

    HAZ

    LV 200- AW/2/Voltage

    LV 200- AW/2/Voltage

    IT 65 - 605-S

    IT 65 - 605-S

    CV 3-Voltage

    CV 3-Voltage

    RAD Elc Int.

    You can submit your request now. Call Now: +98 21 66759575