Follow RAD Elc Int. on Telegram

transducer - For Industry - HO 50...250-S

HO 50...250-S

HO 50...250-S


Distributer:   LEM

Group:   transducer

Subgroup:   For Industry

Dimensions:   

Price:   0

Keywords:   ,



    Share it:        

    Details:

    Main characteristics:

    • 🔷 6 ranges: 50 ARMS, 100 ARMS, 150 ARMS, 200 ARMS, 240 ARMS, 250 ARMS
    • 🔷 Overcurrent detection set @ 2.93 x IPN on a dedicated pin
    • 🔷 Short response time: 3.5 µs
    • 🔷 Access to voltage reference
    • 🔷 Low offset and gain drift
    • 🔷 Measuring range up to 2.5 x IPN
    • 🔷 Small design (22 (W) x 45 (L) x 33 (H))
    • 🔷High accuracy at 25°C: 1% of IPN at 105°C: 4.6% of IPN
    • 🔷 Creepage & clearance distances: 8 mm + CTI 600
    • 🔷 5 years warranty
     

    Features:

    • 🔷 DC, AC and pulse currents measurements with galvanic isolation
    • 🔷 Single supply 0, +5 V or 0, +3.3 V
    • 🔷 Isolation test voltage: up to 4.3 KVRMS / 50 Hz / 1 min
    • 🔷 Panel mounting models
    • 🔷 Big aperture 15 x 8 mm
    • 🔷 Operating temperature range: -40°C to +105°C
    • 🔷 Voltage output (0.8 V @ IPN)
    • 🔷 Bandwidth DC... 250 KHz (-3 dB)

     

    Standard compliance:

    EN 50178 for industrial applications such as:

    • 🔷 Home appliances
    • 🔷 Solar inverters (MPPT)
    • 🔷 Combiner box for solar applications
    • 🔷 Small smart meters
    • 🔷 Servo drives
    • 🔷 AC Variable speed drives
    • 🔷 Power supplies
    • 🔷 UPS
    • 🔷 SMPS
    • 🔷 Forklift trucks
    • 🔷 Air-conditioners
    • 🔷 Current monitoring
    • 🔷 Welding applications
    • 🔷 UL 508 (UR marking)
    • 🔷 Using UL94-VO recognized materials
    • 🔷 European Directive EMC 2004 / 108 / EEC: CE marking
    • 🔷 Low voltage directive 2006 / 95 / EEC
    • 🔷 IEC 61010-1 safety

     

    Remarks:

    • 🔷 Bipolar currents measurements when single supplied 0/+5 V or 0/+3.3 V
    • 🔷 Fault reporting: Memory check

     

    Product search results
    Model Expand Primary
    Nominal
    Value
    Measuring
    Range
    Secondary
    Nominal
    Signal
    Supply
    Voltage (V)
    Accuracy (%) Mounting
     
    HO 100-S-0100 expand 100 A 250 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 100-S/SP33-1106 expand 100 A 250 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 150-S-0100 expand 150 A 375 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 150-S/SP33-1106 expand 150 A 375 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 200-S-0100 expand 200 A 500 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 200-S/SP33-1106 expand 200 A 500 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 240-S-0100 expand 240 A 600 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 250-S-0100 expand 250 A 625 A 0.8 V 5-5 Uni 1 On primary fastening, Panel
    HO 250-S/SP33-1106 expand 250 A 625 A 0.46 V 3.3-3.3 Uni 1 On primary fastening, Panel
    HO 50-S-0100 expand 50 A 125 A 0.8 V 5-5 Uni 1.25 On primary fastening, Panel
    HO 50-S/SP33-1106 expand 50 A 125 A 0.46 V 3.3-3.3 Uni 1.25 On primary fastening, Panel
     

     

    Similar Products

    LV 200-AW/2

    LV 200-AW/2

    LV 100

    LV 100

    CV 4-Voltage

    CV 4-Voltage

    HAT

    HAT

    IST

    IST

    LA 306-S

    LA 306-S

    LA 205 / 305 -S/ -T

    LA 205 / 305 -S/ -T

    LV 200- AW/2/Voltage

    LV 200- AW/2/Voltage

    HTA

    HTA

    HAC

    HAC

    HAZ

    HAZ

    HAS

    HAS

    IT 65 - 605-S

    IT 65 - 605-S

    LV 25-P

    LV 25-P

    HAX

    HAX

    HAIS

    HAIS

    RAD Elc Int.