    Details:

    Main characteristics:

    • Nominal current measurement: from 60 and 600 ADC
    • Excellent linearity, better than 12 ppm over temperature range
    • High resolution
    • Very low offset over temperature range from 36 to 400 ppm
    • Overall accuracy @ IPN between < +/- 0.004 % to 0.04 % over temperature range
    • Wide frequency bandwidth up to 1000 kHz (+/- 3 dB)

     

    Features:

    • DC, AC pulse currents measurements with galvanic isolation
    • Fluxgate technology
    • Electrostatic shield between primary and secondary circuit
    • Power supply +/-15 V
    • Operating temperature range from -40 to +85°C
    • D-Sub 9 male interface output
    • Current output
    • Really quick response time (<0.5 µs)

     

    Standard compliance:

    • European Directive EMC 2004 / 108 / EEC : CE Marking
    • Typical applications:
      • Feedback element in high performance gradient amplifiers for MRI
      • Feedback element in precision current regulated devices (power supplies…)
      • Precise and high stability inverters
      • Medical equipment
      • Energy measurement
      • Power analyzers
      • Calibration units
      • Test and Measurement equipment

     

    Remarks:

    • Current overload capability
    • Additional output indicating the transducer state
    • A LED shows normal operation
    • Expected to accommodate round primary conductors of 26 and 30 mm diameter (according to model used)

    Product search results
    Model Expand Primary
    Nominal
    Value
    Measuring
    Range
    Secondary
    Nominal
    Signal
    Supply
    Voltage (V)
    Accuracy (%) Mounting
     
    IT 205-S ULTRASTAB expand 200 A 283 A 200 mA 15-15 Bi 0.01 Panel
      Technology: Closed loop Fluxgate IT type  
    IT 405-S ULTRASTAB expand 400 A 566 A 266 mA 15-15 Bi 0.0047 Panel
      Technology: Closed loop Fluxgate IT type  
    IT 605-S ULTRASTAB expand 600 A 849 A 400 mA 15-15 Bi 0.0032 Panel
      Technology: Closed loop Fluxgate IT type  
    IT 65-S ULTRASTAB expand 60 A 85 A 100 mA 15-15 Bi 0.03 Panel
      Technology: Closed loop Fluxgate IT type  
     

    Similar Products

    CV 4-Voltage

    CV 4-Voltage

    LV 200-AW/2

    LV 200-AW/2

    HO 8-NSM

    HO 8-NSM

    HO 25-NSMPR

    HO 25-NSMPR

    HO xx-P

    HO xx-P

    DVL voltage

    DVL voltage

    LA 306-S

    LA 306-S

    HLSR xx-SM

    HLSR xx-SM

    LV 100-Voltage 1

    LV 100-Voltage 1

    HO 60...250-P

    HO 60...250-P

    LAX 100-NP

    LAX 100-NP

    LA 205 / 305 -S/ -T

    LA 205 / 305 -S/ -T

    LA 25-200 -P

    LA 25-200 -P

    LV 200- AW/2/Voltage

    LV 200- AW/2/Voltage

    IT 65 - 605-S

    IT 65 - 605-S

    HOP-HTR

    HOP-HTR

    RAD Elc Int.

    You can submit your request now. Call Now: +98 21 66759575